Water Ranges
-- .4 to 300 GPM (1 to 1000 LPM)
Pipe sizes: 3/8" to 12"
Coil sensor option
-- Distance up to 200 feet (61 meters)
-- Requires no external power
-- AC sine wave output signal
-- Coil generates AC voltage
From .06 volts to approximately 3 volts, depending on the flow rate
Hall Effect sensor option
-- Distance up to 1 mile (1.61 km)
-- TTL/CMOS compatible digital (current sinking) output signal
-- DC square wave output signal
-- Power required
> Customer supply power (6-24V DC absolute)
> 115V AC plug in transformer
> 220V AC plug in transformer
> 230V AC plug in transformer